COPPER TEST KIT
Copper
Test kit for performing colorimetric tests
on copper ions in surfacewater and sewage
RANGE
0.1 - 1.5 mg/l
RANGE
0.1 - 1.5 mg/l
Method:
Combined with caparison [oxalic acid bis(cyclohexylidene hydrazide)],
copper
(II) ions form a blue complex in the alkaline range.
Measurement range:
0.1–1.5 mg/L Cu
2+
Contents (*refill pack):
sufficient for 100 tests
30 mL Cu-1*
20 mL Cu-2*
2 screw-plug measuring glasses
1 slide comparator
1 color chart
1 plastic syringe 5 mL
1 instruction for use*
Hazard warning:
This test does not contain any harmful substances which must be
specially
labelled as hazardous.
Instructions for use:
also refer to the pictogram on the back of the color chart
1. Pour a
5 mL water sample
into each of the measuring glasses us-
ing the plastic syringe.
Place a measuring glass on position A in the comparator.
Only add the reagent to measuring glass B.
2. Add
5 drops of Cu-1
, seal the glass and mix.
3. Add
5 drops of Cu-2
, seal the glass and mix.
4. Open the glass after
10 min
and place it on position B in the com-
parator.
5. Slide the comparator until the colors match in the inspection hole on
top. Check the measurement reading in the recess on the compara-
tor reed. Mid-values can be estimated.
6. After use, rinse out both measuring glasses thoroughly and seal
them.
The reagents can be used for the
photometric evaluation
with pho-
tometer PF-12 / PF-12
Plus
.
This technique can be used also for analyzing sea water.
Disposing of the samples:
The used analysis specimens can be flushed down the drain with tap
water and channelled
off to the local sewage treatment works.
Interferences:
Strongly acidic and buffered test samples are to be adjusted to pH 9
with ammonia before determination.
Iron(II), chromium(VI), nickel and manganese ions disrupt tests if they
are present in concentrations in excess
of 10 mg/L. Chromium(III) ions
present in concentrations in excess
of 10 mg/L cause clouding and lead
to limited results. Cobalt ions form a red color complex and, depending
on the concentration of copper, disrupt the tests if present
in concen-
trations from as little as 1 mg/L. If cyanide and sulfide are present in
concentrations in excess of 1 mg/L, they will lead to limited results.
Storage:
Store the test kit in a cool (< 25 °C) and dry place.
ubungi kami untuk info lebih lanjut
ke product apllicant engineering kami
kami tidak hanya menjual tetapi memberikan konsultasi gratis afters sales
dan mitra TERBAIK anda dalam menyediakan kebutuhan alat alat uji test kit atau instrument lainnya
kontak person :
Alfathoni ( Hp/WA = 0812 8910 - 4709 )
email : ms3@purnamalab.com
Rizky ( Hp/Wa = 0813 9889 6309 )
email : ms2@purnamalab.com
head office
PT PURNAM LABORATORY
Pesona Anggrek Harapan Blok E.4 No.1 / E1 No 04 Bekasi Utara 17124
Phone : 021 - 88385761, 0821 2255 5339, Fax : 021 - 8838 5759
Pin BB : 538914A7 WhatsApp : 0878 8895 8140
Email : admin@purnamalab.com,
Website : www.purnamalab.com
ubungi kami untuk info lebih lanjut
ke product apllicant engineering kami
kami tidak hanya menjual tetapi memberikan konsultasi gratis afters sales
dan mitra TERBAIK anda dalam menyediakan kebutuhan alat alat uji test kit atau instrument lainnya
kontak person :
Alfathoni ( Hp/WA = 0812 8910 - 4709 )
email : ms3@purnamalab.com
Rizky ( Hp/Wa = 0813 9889 6309 )
email : ms2@purnamalab.com
head office
PT PURNAM LABORATORY
Pesona Anggrek Harapan Blok E.4 No.1 / E1 No 04 Bekasi Utara 17124
Phone : 021 - 88385761, 0821 2255 5339, Fax : 021 - 8838 5759
Pin BB : 538914A7 WhatsApp : 0878 8895 8140
Email : admin@purnamalab.com,
Website : www.purnamalab.com